T22 UN Portable Tank YCG8320L-X Cylinder T Code System Classifications for ISO Tank Containers
T-Code | Minimum Test Pressure (bar) | Minimum Shell Thickness | Pressure-Relief Requirements | Bottom Opening Requirements |
T1 | 1.5 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T2 | 1.5 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T3 | 2.65 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T4 | 2.65 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T5 | 2.65 | > or = 6mm | normal + rupture disc | Not Allowed |
T6 | 4 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T7 | 4 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T8 | 4 | > or = 6mm | normal | Not Allowed |
T9 | 4 | 6mm | normal | Not Allowed |
T10 | 4 | 6mm | normal + rupture disc | Not Allowed |
T11 | 6 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T12 | 6 | > or = 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T13 | 6 | 6mm | normal | Not Allowed |
T14 | 6 | 6mm | normal + rupture disc | Not Allowed |
T15 | 10 | >or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T16 | 10 | > or = 6mm | normal + rupture disc | |
T17 | 10 | 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T18 | 10 | 6mm | normal + rupture disc | Not Allowed |
T19 | 10 | 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T20 | 10 | 8mm | normal + rupture disc | Not Allowed |
T21 | 10 | 10mm | normal | Not Allowed |
T22 | 10 | 10mm | normal + rupture disc | Not Allowed |
T Code System for ISO Tank Containers and specifications:
In addition to the above types of ISO tank container, there are 2 others, namely, a T50 and a T70.
The T50 is a gas tank and has a minimum test pressure of 57.6 bar. Under the IMO system, this was classified IMO5.
The T70 is a cryogenic tank container designed for carrying liquefied gases. Under the IMO system, this was classified IMO7.
The general design consists of a 20' ISO frame and a tank made of carbon steel with internal lead-lining. The tanks are equipped with a manhole of 20" nominal size. The manhole is located on the top of the tank approx. in the centre of the shell. A working platform is installed in the area of the manhole. The platform is located all around the manhole. Mounting ladders are installed on both longitudinal sides. Filling, discharge and safety devices are installed on top of the manhole covered and protected by dome cover.
The frame dimensions: 20' x 8' x 8' = 6058 x 2438 x 2438 mm. The frame is equipped with corner castings according to ISO regulations. Further handling devices are not installed.
Handling of Containers Attention:
The ISO tank containers of type 20T6, IMDG type T22 are designed for the transport of liquid Bromine.
The approved quality of Bromine is:
• Liquid Bromine Br2,
• Free from acids
• Recommended water content 0.005% or less
• Maximum allowable water content 0.1%
Attention: Water content higher than 0.005% leads to increased corrosion and requires frequent internal inspection.
All relevant national and international regulations for the handling and transport of dangerous goods in general as well as special regulations concerning Bromine have to be observed at any time. Endanger of persons and pollution of environment has to be excluded. For the handling of the tank containers procedures as following are permitted. Lifting / transfer • by spreader fixed to all upper corner castings. This is the preferred method. • by using of traverses and ropes of sufficient strength. The ropes have to be equipped with suitable and approved arresting devices which have to be fixed to the lower corner castings.
Attention: The handling of the containers by using fork lift or similar device is not allowed.
Transportation
• by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations.
• by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container.
We recommend Teflon lined rubber hoses for the unloading of the trucks.
DTA T22 Tank Container | • Liquid Bromine Br2, • Free from acids • Recommended water content 0.005% or less • Maximum allowable water content 0.1% |
Name | 20ft tank container |
Model | T22/ DTAU |
Medium | Liquid bromine UN1744 |
Volume L | 8320 |
External Dimension Mm | 6058*2438*2438 20' x 8' x 8' |
Tank Size Mm | φ1500*5600 |
Design Pressure Bar | 6.67 |
Test Pressure Bar | 10 |
Design Temperature Range | -40℃~65℃ |
Can Body Material | SA516M Gr485 |
Nominal Shell Thickness Mm | 10.13,12 |
Seal Thickness Mm | 10.13,12 |
Anti Corrosion In Tank | LING LEAD 3-6mm |
Net Weight Of Tank Kg | ≈7800 |
Operation Quality Kg | 36000 |
Max Play Loading Kg | 28200 |
Loading And Unloading Type | Top |
Accessories Configuration | Safety valve+bursting disc * 1, DN65 Gas phase valve * 2, DN40 Liquid phase valve (including siphon and liquid trap) * 1, DN40 Manhole * 1, DN500 |
Design/Manufacturing Standards | IMDG CODE 2016,ADR/RID,49CFR,TIR, |
Third Party Inspection | BV/ ASME /TS |
Attention: | The handling of the containers by using fork lift or similar device is not allowed. Transportation • by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations. • by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container. Dong Run ZE recommend Teflon lined rubber hoses for the unloading of the trucks. |
1.Are you trading company or manufacturer ?
We are Group Corporation manufacturer ,have Group Factories Contractor.Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.
T23 PORTABLE TANK INSTRUCTION T23
UN No. | Substance | Minimum test pressure (bar) |
3109 | ORGANIC PEROXIDE, TYPE F, LIQUID tert-Butyl hydro- peroxidea, not more than 72% with water Cumyl hydro-peroxide, not more than 90% in diluent type A Di-tert-butyl peroxide, not more than 32% in diluent type A Isopropyl cumyl hydro- peroxide, not more than 72% in diluent type A p-Menthyl hydro- peroxide, not more than 72% in diluent type A Pinanyl hydro- peroxide, not more than 56% in diluent type A | 4 |
3110 | ORGANIC PEROXIDE TYPE F, SOLID Dicumyl peroxideb | 4 |
3119 | ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED | 4 |
tert-Amyl peroxyneodecanoate, not more than 47% in diluent type A | ||
tert-Butyl peroxyacetate, not more than 32% in diluent type B | ||
tert-Butyl peroxy-2- ethylhexanoate, not more than 32% in diluent type B |
a Provided that steps have been taken to achieve the safety equivalence of 65% tert-Butyl hydroperoxide and 35% water.
b Maximum quantity per portable tank: 2000 kg.
UN No. | Substance | Minimum test pressure (bar) | Control tempe- rature | Emergency temperaturef |
3119 (Cont'd) | tert-Butyl peroxypivalate, not more than 27% in diluent type B | +5 °C | +10 °C | |
tert-Butyl peroxy- 3,5,5-trimethyl- hexanoate, not more than 32% in diluent type B | +35 °C | +40 °C | ||
Di-(3,5,5-trimethyl- hexanoyl) peroxide, not more than 38% in diluent type A or type B | 0 °C | +5 °C | ||
Peroxyacetic acid, distilled, type F, stabilizedd | +30 °C | +35 °C | ||
3120 | ORGANIC PEROXIDE, TYPE F, SOLID, TEMPERATURE CONTROLLED | 4 | c | c |
3229 | SELF-REACTIVE LIQUID TYPE F | 4 | ||
3230 | SELF-REACTIVE SOLID TYPE F | 4 | ||
3239 | SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
3240 | SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1005 | Ammonia, anhydrous | 29.0 25.7 22.0 19.7 | Allowed | 0.53 |
1009 | Bromotrifluoromethane (Refrigerant gas R 13B1) | 38.0 34.0 30.0 27.5 | Allowed | 1.13 |
1010 | Butadienes, stabilized | 7.5 7.0 7.0 7.0 | Allowed | 0.55 |
1010 | Butadienes and hydrocarbon mixture, stabilized | Allowed | ||
1011 | Butane | 7.0 7.0 7.0 7.0 | Allowed | 0.51 |
1012 | Butylene | 8.0 7.0 7.0 7.0 | Allowed | 0.53 |
1017 | Chlorine | 19.0 17.0 15.0 13.5 | Not Allowed | 1.25 |
1018 | Chlorodifluoromethane (Refrigerant gas R 22) | 26.0 24.0 21.0 19.0 | Allowed | 1.03 |
1020 | Chloropentafluoroethane (Refrigerant gas R 115) | 23.0 20.0 18.0 16.0 | Allowed | 1.06 |
1021 | 1-Chloro- 1,2,2,2-tetrafluoroethane (Refrigerant gas R 124) | 10.3 9.8 7.9 7.0 | Allowed | 1.20 |
1027 | Cyclopropane | 18.0 16.0 14.5 13.0 | Allowed | 0.53 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1028 | Dichlorodifluoromethane (Refrigerant gas R 12) | 16.0 15.0 13.0 11.5 | Allowed | 1.15 |
1029 | Dichlorofluoromethane (Refrigerant gas R 21) | 7.0 7.0 7.0 7.0 | Allowed | 1.23 |
1030 | 1,1-Difluoroethane (Refrigerant gas R 152a) | 16.0 14.0 12.4 11.0 | Allowed | 0.79 |
1032 | Dimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.59 |
1033 | Dimethyl ether | 15.5 13.8 12.0 10.6 | Allowed | 0.58 |
1036 | Ethylamine | 7.0 7.0 7.0 7.0 | Allowed | 0.61 |
1037 | Ethyl chloride | 7.0 7.0 7.0 7.0 | Allowed | 0.80 |
1040 | Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 °C | - - - 10.0 | Not Allowed | 0.78 |
1041 | Ethylene oxide and carbon dioxide mixture with more than 9% but not more than 87% ethylene oxide | Allowed | ||
1055 | Isobutylene | 8.1 7.0 7.0 7.0 | Allowed | 0.52 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1060 | Methylacetylene and propadiene mixture, stabilized | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1061 | Methylamine, anhydrous | 10.8 9.6 7.8 7.0 | Allowed | 0.58 |
1062 | Methyl bromide with not more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1063 | Methyl chloride (Refrigerant gas R 40) | 14.5 12.7 11.3 10.0 | Allowed | 0.81 |
1064 | Methyl mercaptan | 7.0 7.0 7.0 7.0 | Not Allowed | 0.78 |
1067 | Dinitrogen tetroxide | 7.0 7.0 7.0 7.0 | Not Allowed | 1.30 |
1075 | Petroleum gases, liquefied | Allowed | ||
1077 | Propylene | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1078 | Refrigerant gas, n.o.s. | Allowed | ||
1079 | Sulphur dioxide | 11.6 10.3 8.5 7.6 | Not Allowed | 1.23 |
1082 | Trifluorochloroethylene, stabilized (Refrigerant gas R 1113) | 17.0 15.0 13.1 11.6 | Not Allowed | 1.13 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1083 | Trimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.56 |
1085 | Vinyl bromide, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 1.37 |
1086 | Vinyl chloride, stabilized | 10.6 9.3 8.0 7.0 | Allowed | 0.81 |
1087 | Vinyl methyl ether, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 0.67 |
1581 | Chloropicrin and methyl bromide mixture with more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1582 | Chloropicrin and methyl chloride mixture | 19.2 16.9 15.1 13.1 | Not Allowed | 0.81 |
1858 | Hexafluoropropylene (Refrigerant gas R 1216) | 19.2 16.9 15.1 13.1 | Allowed | 1.11 |
1912 | Methyl chloride and methylene chloride mixture | 15.2 13.0 11.6 10.1 | Allowed | 0.81 |
1958 | 1,2-Dichloro-1,1,2,2- tetrafluoroethane (Refrigerant gas R 114) | 7.0 7.0 7.0 7.0 | Allowed | 1.30 |
1965 | Hydrocarbon gas, mixture liquefied, n.o.s. | Allowed | ||
1969 | Isobutane | 8.5 7.5 7.0 7.0 | Allowed | 0.49 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio | |
1973 | Chlorodifluoromethane and chloropentafluoroethane mixture with fixed boiling point, with approximately 49% chlorodifluoromethane (Refrigerant gas R 502) | 28.3 25.3 22.8 20.3 | Allowed | Normal | 1.05 |
1974 | Chlorodifluorobromomethane (Refrigerant gas R 12B1) | 7.4 7.0 7.0 7.0 | Allowed | Normal | 1.61 |
1976 | Octafluorocyclobutane (Refrigerant gas RC 318) | 8.8 7.8 7.0 7.0 | Allowed | Normal | 1.34 |
1978 | Propane | 22.5 20.4 18.0 16.5 | Allowed | Normal | 0.42 |
1983 | 1-Chloro-2,2,2-trifluoroethane (Refrigerant gas R 133a) | 7.0 7.0 7.0 7.0 | Allowed | Normal | 1.18 |
2035 | 1,1,1-Trifluoroethane (Refrigerant gas R 143a) | 31.0 27.5 24.2 21.8 | Allowed | Normal | 0.76 |
2424 | Octafluoropropane (Refrigerant gas R 218) | 23.1 20.8 18.6 16.6 | Allowed | Normal | 1.07 |
2517 | 1-Chloro-1,1-difluoroethane (Refrigerant gas R 142b) | 8.9 7.8 7.0 7.0 | Allowed | Normal | 0.99 |
2602 | Dichlorodifluoromethane and 1,1-difluoroethane azeotropic mixture with approximately 74% dichlorodifluoromethane (Refrigerant gas R 500) | 20.0 18.0 16.0 14.5 | Allowed | Normal | 1.01 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Pressure- relief requirementsb | Maximum filling ratio |
3057 | Trifluoroacetyl chloride | 14.6 12.9 11.3 9.9 | Not allowed | 1.17 | |
3070 | Ethylene oxide and dichlorodifluoromethane mixture with not more than 12.5% ethylene oxide | 14.0 12.0 11.0 9.0 | Allowed | 1.09 | |
3153 | Perfluoro (methyl vinyl ether) | 14.3 13.4 11.2 10.2 | Allowed | Normal | 1.14 |
3159 | 1,1,1,2-Tetrafluoroethane (Refrigerant gas R 134a) | 17.7 15.7 13.8 12.1 | Allowed | Normal | 1.04 |
3161 | Liquefied gas, flammable, n.o.s. | Allowed | Normal | ||
3163 | Liquefied gas, n.o.s. | Allowed | Normal | ||
3220 | Pentafluoroethane (Refrigerant gas R 125) | 34.4 30.8 27.5 24.5 | Allowed | Normal | 0.87 |
3252 | Difluoromethane (Refrigerant gas R 32) | 43.0 39.0 34.4 30.5 | Allowed | Normal | 0.78 |
3296 | Heptafluoropropane (Refrigerant gas R 227) | 16.0 14.0 12.5 11.0 | Allowed | Normal | 1.20 |
3297 | Ethylene oxide and chlorotetrafluoroethane mixture, with not more than 8.8% ethylene oxide | 8.1 7.0 7.0 7.0 | Allowed | Normal | 1.16 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio | |
3298 | Ethylene oxide and pentafluoroethane mixture, with not more than 7.9% ethylene oxide | 25.9 23.4 20.9 18.6 | Allowed | Normal | 1.02 |
3299 | Ethylene oxide and tetrafluoroethane mixture, with not more than 5.6% ethylene oxide | 16.7 14.7 12.9 11.2 | Allowed | Normal | 1.03 |
3318 | Ammonia solution, relative density less than 0.880 at 15 °C in water, with more than 50% ammonia | Allowed | |||
3337 | Refrigerant gas R 404A | 31.6 28.3 25.3 22.5 | Allowed | Normal | 0.84 |
3338 | Refrigerant gas R 407A | 31.3 28.1 25.1 22.4 | Allowed | Normal | 0.95 |
3339 | Refrigerant gas R 407B | 33.0 29.6 26.5 23.6 | Allowed | Normal | 0.95 |
3340 | Refrigerant gas R 407C | 29.9 26.8 23.9 21.3 | Allowed | Normal | 0.95 |
3500 | Chemical under pressure, n.o.s. | Allowed | TP43c | ||
3501 | Chemical under pressure, flammable, n.o.s. | Allowed | TP4c | ||
3502 | Chemical under pressure, toxic, n.o.s. | Allowed | TP4c | ||
3503 | Chemical under pressure, corrosive, n.o.s. | Allowed | TP4c | ||
3504 | Chemical under pressure, flammable, toxic, n.o.s. | Allowed | TP4c | ||
3505 | Chemical under pressure, flammable, corrosive, n.o.s. | Allowed | TP4c |
Lead Lining Bromine T22 UN Portable
ISO 20ft Tank Container 8.32m3 (Bromine Br2 isotanks UN1744)
6.67Bar 20K2 ISOTank UN1744 IMDG/ADR/RID BROMINE BROMINE SOLUTIONN. UN1744
TC IMPACT APPROVED Bromine Storage Tanks
ISO's ranging in capacity from 6870 Liter to 8230 Liter ,9130 Liter Capacities.
T22 UN Portable Tank YCG8320L-X Cylinder T Code System Classifications for ISO Tank Containers
T-Code | Minimum Test Pressure (bar) | Minimum Shell Thickness | Pressure-Relief Requirements | Bottom Opening Requirements |
T1 | 1.5 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T2 | 1.5 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T3 | 2.65 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T4 | 2.65 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T5 | 2.65 | > or = 6mm | normal + rupture disc | Not Allowed |
T6 | 4 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T7 | 4 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T8 | 4 | > or = 6mm | normal | Not Allowed |
T9 | 4 | 6mm | normal | Not Allowed |
T10 | 4 | 6mm | normal + rupture disc | Not Allowed |
T11 | 6 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T12 | 6 | > or = 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T13 | 6 | 6mm | normal | Not Allowed |
T14 | 6 | 6mm | normal + rupture disc | Not Allowed |
T15 | 10 | >or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T16 | 10 | > or = 6mm | normal + rupture disc | |
T17 | 10 | 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T18 | 10 | 6mm | normal + rupture disc | Not Allowed |
T19 | 10 | 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T20 | 10 | 8mm | normal + rupture disc | Not Allowed |
T21 | 10 | 10mm | normal | Not Allowed |
T22 | 10 | 10mm | normal + rupture disc | Not Allowed |
T Code System for ISO Tank Containers and specifications:
In addition to the above types of ISO tank container, there are 2 others, namely, a T50 and a T70.
The T50 is a gas tank and has a minimum test pressure of 57.6 bar. Under the IMO system, this was classified IMO5.
The T70 is a cryogenic tank container designed for carrying liquefied gases. Under the IMO system, this was classified IMO7.
The general design consists of a 20' ISO frame and a tank made of carbon steel with internal lead-lining. The tanks are equipped with a manhole of 20" nominal size. The manhole is located on the top of the tank approx. in the centre of the shell. A working platform is installed in the area of the manhole. The platform is located all around the manhole. Mounting ladders are installed on both longitudinal sides. Filling, discharge and safety devices are installed on top of the manhole covered and protected by dome cover.
The frame dimensions: 20' x 8' x 8' = 6058 x 2438 x 2438 mm. The frame is equipped with corner castings according to ISO regulations. Further handling devices are not installed.
Handling of Containers Attention:
The ISO tank containers of type 20T6, IMDG type T22 are designed for the transport of liquid Bromine.
The approved quality of Bromine is:
• Liquid Bromine Br2,
• Free from acids
• Recommended water content 0.005% or less
• Maximum allowable water content 0.1%
Attention: Water content higher than 0.005% leads to increased corrosion and requires frequent internal inspection.
All relevant national and international regulations for the handling and transport of dangerous goods in general as well as special regulations concerning Bromine have to be observed at any time. Endanger of persons and pollution of environment has to be excluded. For the handling of the tank containers procedures as following are permitted. Lifting / transfer • by spreader fixed to all upper corner castings. This is the preferred method. • by using of traverses and ropes of sufficient strength. The ropes have to be equipped with suitable and approved arresting devices which have to be fixed to the lower corner castings.
Attention: The handling of the containers by using fork lift or similar device is not allowed.
Transportation
• by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations.
• by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container.
We recommend Teflon lined rubber hoses for the unloading of the trucks.
DTA T22 Tank Container | • Liquid Bromine Br2, • Free from acids • Recommended water content 0.005% or less • Maximum allowable water content 0.1% |
Name | 20ft tank container |
Model | T22/ DTAU |
Medium | Liquid bromine UN1744 |
Volume L | 8320 |
External Dimension Mm | 6058*2438*2438 20' x 8' x 8' |
Tank Size Mm | φ1500*5600 |
Design Pressure Bar | 6.67 |
Test Pressure Bar | 10 |
Design Temperature Range | -40℃~65℃ |
Can Body Material | SA516M Gr485 |
Nominal Shell Thickness Mm | 10.13,12 |
Seal Thickness Mm | 10.13,12 |
Anti Corrosion In Tank | LING LEAD 3-6mm |
Net Weight Of Tank Kg | ≈7800 |
Operation Quality Kg | 36000 |
Max Play Loading Kg | 28200 |
Loading And Unloading Type | Top |
Accessories Configuration | Safety valve+bursting disc * 1, DN65 Gas phase valve * 2, DN40 Liquid phase valve (including siphon and liquid trap) * 1, DN40 Manhole * 1, DN500 |
Design/Manufacturing Standards | IMDG CODE 2016,ADR/RID,49CFR,TIR, |
Third Party Inspection | BV/ ASME /TS |
Attention: | The handling of the containers by using fork lift or similar device is not allowed. Transportation • by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations. • by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container. Dong Run ZE recommend Teflon lined rubber hoses for the unloading of the trucks. |
1.Are you trading company or manufacturer ?
We are Group Corporation manufacturer ,have Group Factories Contractor.Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.
T23 PORTABLE TANK INSTRUCTION T23
UN No. | Substance | Minimum test pressure (bar) |
3109 | ORGANIC PEROXIDE, TYPE F, LIQUID tert-Butyl hydro- peroxidea, not more than 72% with water Cumyl hydro-peroxide, not more than 90% in diluent type A Di-tert-butyl peroxide, not more than 32% in diluent type A Isopropyl cumyl hydro- peroxide, not more than 72% in diluent type A p-Menthyl hydro- peroxide, not more than 72% in diluent type A Pinanyl hydro- peroxide, not more than 56% in diluent type A | 4 |
3110 | ORGANIC PEROXIDE TYPE F, SOLID Dicumyl peroxideb | 4 |
3119 | ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED | 4 |
tert-Amyl peroxyneodecanoate, not more than 47% in diluent type A | ||
tert-Butyl peroxyacetate, not more than 32% in diluent type B | ||
tert-Butyl peroxy-2- ethylhexanoate, not more than 32% in diluent type B |
a Provided that steps have been taken to achieve the safety equivalence of 65% tert-Butyl hydroperoxide and 35% water.
b Maximum quantity per portable tank: 2000 kg.
UN No. | Substance | Minimum test pressure (bar) | Control tempe- rature | Emergency temperaturef |
3119 (Cont'd) | tert-Butyl peroxypivalate, not more than 27% in diluent type B | +5 °C | +10 °C | |
tert-Butyl peroxy- 3,5,5-trimethyl- hexanoate, not more than 32% in diluent type B | +35 °C | +40 °C | ||
Di-(3,5,5-trimethyl- hexanoyl) peroxide, not more than 38% in diluent type A or type B | 0 °C | +5 °C | ||
Peroxyacetic acid, distilled, type F, stabilizedd | +30 °C | +35 °C | ||
3120 | ORGANIC PEROXIDE, TYPE F, SOLID, TEMPERATURE CONTROLLED | 4 | c | c |
3229 | SELF-REACTIVE LIQUID TYPE F | 4 | ||
3230 | SELF-REACTIVE SOLID TYPE F | 4 | ||
3239 | SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
3240 | SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1005 | Ammonia, anhydrous | 29.0 25.7 22.0 19.7 | Allowed | 0.53 |
1009 | Bromotrifluoromethane (Refrigerant gas R 13B1) | 38.0 34.0 30.0 27.5 | Allowed | 1.13 |
1010 | Butadienes, stabilized | 7.5 7.0 7.0 7.0 | Allowed | 0.55 |
1010 | Butadienes and hydrocarbon mixture, stabilized | Allowed | ||
1011 | Butane | 7.0 7.0 7.0 7.0 | Allowed | 0.51 |
1012 | Butylene | 8.0 7.0 7.0 7.0 | Allowed | 0.53 |
1017 | Chlorine | 19.0 17.0 15.0 13.5 | Not Allowed | 1.25 |
1018 | Chlorodifluoromethane (Refrigerant gas R 22) | 26.0 24.0 21.0 19.0 | Allowed | 1.03 |
1020 | Chloropentafluoroethane (Refrigerant gas R 115) | 23.0 20.0 18.0 16.0 | Allowed | 1.06 |
1021 | 1-Chloro- 1,2,2,2-tetrafluoroethane (Refrigerant gas R 124) | 10.3 9.8 7.9 7.0 | Allowed | 1.20 |
1027 | Cyclopropane | 18.0 16.0 14.5 13.0 | Allowed | 0.53 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1028 | Dichlorodifluoromethane (Refrigerant gas R 12) | 16.0 15.0 13.0 11.5 | Allowed | 1.15 |
1029 | Dichlorofluoromethane (Refrigerant gas R 21) | 7.0 7.0 7.0 7.0 | Allowed | 1.23 |
1030 | 1,1-Difluoroethane (Refrigerant gas R 152a) | 16.0 14.0 12.4 11.0 | Allowed | 0.79 |
1032 | Dimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.59 |
1033 | Dimethyl ether | 15.5 13.8 12.0 10.6 | Allowed | 0.58 |
1036 | Ethylamine | 7.0 7.0 7.0 7.0 | Allowed | 0.61 |
1037 | Ethyl chloride | 7.0 7.0 7.0 7.0 | Allowed | 0.80 |
1040 | Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 °C | - - - 10.0 | Not Allowed | 0.78 |
1041 | Ethylene oxide and carbon dioxide mixture with more than 9% but not more than 87% ethylene oxide | Allowed | ||
1055 | Isobutylene | 8.1 7.0 7.0 7.0 | Allowed | 0.52 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1060 | Methylacetylene and propadiene mixture, stabilized | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1061 | Methylamine, anhydrous | 10.8 9.6 7.8 7.0 | Allowed | 0.58 |
1062 | Methyl bromide with not more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1063 | Methyl chloride (Refrigerant gas R 40) | 14.5 12.7 11.3 10.0 | Allowed | 0.81 |
1064 | Methyl mercaptan | 7.0 7.0 7.0 7.0 | Not Allowed | 0.78 |
1067 | Dinitrogen tetroxide | 7.0 7.0 7.0 7.0 | Not Allowed | 1.30 |
1075 | Petroleum gases, liquefied | Allowed | ||
1077 | Propylene | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1078 | Refrigerant gas, n.o.s. | Allowed | ||
1079 | Sulphur dioxide | 11.6 10.3 8.5 7.6 | Not Allowed | 1.23 |
1082 | Trifluorochloroethylene, stabilized (Refrigerant gas R 1113) | 17.0 15.0 13.1 11.6 | Not Allowed | 1.13 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1083 | Trimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.56 |
1085 | Vinyl bromide, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 1.37 |
1086 | Vinyl chloride, stabilized | 10.6 9.3 8.0 7.0 | Allowed | 0.81 |
1087 | Vinyl methyl ether, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 0.67 |
1581 | Chloropicrin and methyl bromide mixture with more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1582 | Chloropicrin and methyl chloride mixture | 19.2 16.9 15.1 13.1 | Not Allowed | 0.81 |
1858 | Hexafluoropropylene (Refrigerant gas R 1216) | 19.2 16.9 15.1 13.1 | Allowed | 1.11 |
1912 | Methyl chloride and methylene chloride mixture | 15.2 13.0 11.6 10.1 | Allowed | 0.81 |
1958 | 1,2-Dichloro-1,1,2,2- tetrafluoroethane (Refrigerant gas R 114) | 7.0 7.0 7.0 7.0 | Allowed | 1.30 |
1965 | Hydrocarbon gas, mixture liquefied, n.o.s. | Allowed | ||
1969 | Isobutane | 8.5 7.5 7.0 7.0 | Allowed | 0.49 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio | |
1973 | Chlorodifluoromethane and chloropentafluoroethane mixture with fixed boiling point, with approximately 49% chlorodifluoromethane (Refrigerant gas R 502) | 28.3 25.3 22.8 20.3 | Allowed | Normal | 1.05 |
1974 | Chlorodifluorobromomethane (Refrigerant gas R 12B1) | 7.4 7.0 7.0 7.0 | Allowed | Normal | 1.61 |
1976 | Octafluorocyclobutane (Refrigerant gas RC 318) | 8.8 7.8 7.0 7.0 | Allowed | Normal | 1.34 |
1978 | Propane | 22.5 20.4 18.0 16.5 | Allowed | Normal | 0.42 |
1983 | 1-Chloro-2,2,2-trifluoroethane (Refrigerant gas R 133a) | 7.0 7.0 7.0 7.0 | Allowed | Normal | 1.18 |
2035 | 1,1,1-Trifluoroethane (Refrigerant gas R 143a) | 31.0 27.5 24.2 21.8 | Allowed | Normal | 0.76 |
2424 | Octafluoropropane (Refrigerant gas R 218) | 23.1 20.8 18.6 16.6 | Allowed | Normal | 1.07 |
2517 | 1-Chloro-1,1-difluoroethane (Refrigerant gas R 142b) | 8.9 7.8 7.0 7.0 | Allowed | Normal | 0.99 |
2602 | Dichlorodifluoromethane and 1,1-difluoroethane azeotropic mixture with approximately 74% dichlorodifluoromethane (Refrigerant gas R 500) | 20.0 18.0 16.0 14.5 | Allowed | Normal | 1.01 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Pressure- relief requirementsb | Maximum filling ratio |
3057 | Trifluoroacetyl chloride | 14.6 12.9 11.3 9.9 | Not allowed | 1.17 | |
3070 | Ethylene oxide and dichlorodifluoromethane mixture with not more than 12.5% ethylene oxide | 14.0 12.0 11.0 9.0 | Allowed | 1.09 | |
3153 | Perfluoro (methyl vinyl ether) | 14.3 13.4 11.2 10.2 | Allowed | Normal | 1.14 |
3159 | 1,1,1,2-Tetrafluoroethane (Refrigerant gas R 134a) | 17.7 15.7 13.8 12.1 | Allowed | Normal | 1.04 |
3161 | Liquefied gas, flammable, n.o.s. | Allowed | Normal | ||
3163 | Liquefied gas, n.o.s. | Allowed | Normal | ||
3220 | Pentafluoroethane (Refrigerant gas R 125) | 34.4 30.8 27.5 24.5 | Allowed | Normal | 0.87 |
3252 | Difluoromethane (Refrigerant gas R 32) | 43.0 39.0 34.4 30.5 | Allowed | Normal | 0.78 |
3296 | Heptafluoropropane (Refrigerant gas R 227) | 16.0 14.0 12.5 11.0 | Allowed | Normal | 1.20 |
3297 | Ethylene oxide and chlorotetrafluoroethane mixture, with not more than 8.8% ethylene oxide | 8.1 7.0 7.0 7.0 | Allowed | Normal | 1.16 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio | |
3298 | Ethylene oxide and pentafluoroethane mixture, with not more than 7.9% ethylene oxide | 25.9 23.4 20.9 18.6 | Allowed | Normal | 1.02 |
3299 | Ethylene oxide and tetrafluoroethane mixture, with not more than 5.6% ethylene oxide | 16.7 14.7 12.9 11.2 | Allowed | Normal | 1.03 |
3318 | Ammonia solution, relative density less than 0.880 at 15 °C in water, with more than 50% ammonia | Allowed | |||
3337 | Refrigerant gas R 404A | 31.6 28.3 25.3 22.5 | Allowed | Normal | 0.84 |
3338 | Refrigerant gas R 407A | 31.3 28.1 25.1 22.4 | Allowed | Normal | 0.95 |
3339 | Refrigerant gas R 407B | 33.0 29.6 26.5 23.6 | Allowed | Normal | 0.95 |
3340 | Refrigerant gas R 407C | 29.9 26.8 23.9 21.3 | Allowed | Normal | 0.95 |
3500 | Chemical under pressure, n.o.s. | Allowed | TP43c | ||
3501 | Chemical under pressure, flammable, n.o.s. | Allowed | TP4c | ||
3502 | Chemical under pressure, toxic, n.o.s. | Allowed | TP4c | ||
3503 | Chemical under pressure, corrosive, n.o.s. | Allowed | TP4c | ||
3504 | Chemical under pressure, flammable, toxic, n.o.s. | Allowed | TP4c | ||
3505 | Chemical under pressure, flammable, corrosive, n.o.s. | Allowed | TP4c |