Stainless L4BN ISO T11 UN Portable Tanks 26KL

More >>
NEW STOCK
PRODUCT DETAIL
You are here: Home » ISO Tank » Chemical Liquids ISO Tank » ISO 20FT T22 UN 1744 Portable Tank Container For 8.32m3 Bromine Br2

ISO 20FT T22 UN 1744 Portable Tank Container For 8.32m3 Bromine Br2

5 0 Reviews
Share to:
sharethis sharing button
ISO 20FT T22 UN 1744 Portable Tank Container For 8.32m3 Bromine Br2
Price: $ 80800
Discount Price: $ 75800
Availability:
Quantity:
min order: 1
View wholesale prices View wholesale prices
  • Quantity Price
  • 1 $-1800
  • 5 $-2800
  • 10 $-3800
  • 20 $-4800
  • 40 $-5800
sign in to view wholesale price

Lead Lining Bromine T22 UN Portable 

ISO 20ft Tank Container 8.32m3 (Bromine Br2 isotanks UN1744)

6.67Bar 20K2 ISOTank  UN1744 IMDG/ADR/RID  BROMINE    BROMINE SOLUTIONN.  UN1744

TC IMPACT APPROVED Bromine Storage Tanks

ISO's ranging in capacity from 6870 Liter to 8230 Liter ,9130 Liter Capacities.

T22 UN Portable Tank YCG8320L-X Cylinder T Code System Classifications for ISO Tank Containers



T Code System for ISO Tank Containers and specifications:

T-Code

Minimum Test Pressure (bar)

Minimum Shell Thickness

Pressure-Relief Requirements

Bottom Opening Requirements

T1

1.5

> or = 6mm

normal

2 shut-off devices (Int + Ext)

T2

1.5

> or = 6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T3

2.65

> or = 6mm

normal

2 shut-off devices (Int + Ext)

T4

2.65

> or = 6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T5

2.65

> or = 6mm

normal + rupture disc

Not Allowed

T6

4

> or = 6mm

normal

2 shut-off devices (Int + Ext)

T7

4

> or = 6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T8

4

> or = 6mm

normal

Not Allowed

T9

4

6mm

normal

Not Allowed

T10

4

6mm

normal + rupture disc

Not Allowed

T11

6

> or = 6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T12

6

> or = 6mm

normal + rupture disc

3 shut-off devices (Int + Ext + cap/blank)

T13

6

6mm

normal

Not Allowed

T14

6

6mm

normal + rupture disc

Not Allowed

T15

10

>or = 6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T16

10

> or = 6mm

normal + rupture disc

T17

10

6mm

normal

3 shut-off devices (Int + Ext + cap/blank)

T18

10

6mm

normal + rupture disc

Not Allowed

T19

10

6mm

normal + rupture disc

3 shut-off devices (Int + Ext + cap/blank)

T20

10

8mm

normal + rupture disc

Not Allowed

T21

10

10mm

normal

Not Allowed

T22

10

10mm

normal + rupture disc

Not Allowed

T Code System for ISO Tank Containers and specifications:

In addition to the above types of ISO tank container, there are 2 others, namely, a T50 and a T70.

The T50 is a gas tank and has a minimum test pressure of 57.6 bar. Under the IMO system, this was classified IMO5.

The T70 is a cryogenic tank container designed for carrying liquefied gases. Under the IMO system, this was classified IMO7.

Product Description


The general design consists of a 20' ISO frame and a tank made of carbon steel with internal lead-lining. The tanks are equipped with a manhole of 20" nominal size. The manhole is located on the top of the tank approx. in the centre of the shell. A working platform is installed in the area of the manhole. The platform is located all around the manhole. Mounting ladders are installed on both longitudinal sides. Filling, discharge and safety devices are installed on top of the manhole covered and protected by dome cover.

The frame dimensions: 20' x 8' x 8' = 6058 x 2438 x 2438 mm. The frame is equipped with corner castings according to ISO regulations. Further handling devices are not installed.


Handling of Containers Attention:

The ISO tank containers of type 20T6, IMDG type T22 are designed for the transport of liquid Bromine.

The approved quality of Bromine is:

• Liquid Bromine Br2,

• Free from acids

• Recommended water content 0.005% or less

• Maximum allowable water content 0.1%


Attention: Water content higher than 0.005% leads to increased corrosion and requires frequent internal inspection.

All relevant national and international regulations for the handling and transport of dangerous goods in general as well as special regulations concerning Bromine have to be observed at any time. Endanger of persons and pollution of environment has to be excluded. For the handling of the tank   containers procedures as following are permitted. Lifting / transfer • by spreader fixed to all upper corner castings. This is the preferred method. • by using of traverses and ropes of sufficient strength. The ropes have to be equipped with suitable and approved arresting devices which have to be fixed to the lower corner castings.


Attention: The handling of the containers by using fork lift or similar device is not allowed.

Transportation

• by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations.

• by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container.

We recommend Teflon lined rubber hoses for the unloading of the trucks.

DTA

T22 Tank Container

• Liquid Bromine Br2,

• Free from acids

• Recommended water content 0.005% or less

• Maximum allowable water content 0.1%

Name

20ft tank container

Model

T22/ DTAU

Medium

Liquid bromine UN1744

Volume L

8320

External Dimension Mm

6058*2438*2438

20' x 8' x 8'

Tank Size Mm

φ1500*5600

Design Pressure Bar

6.67

Test Pressure Bar

10

Design Temperature Range

-40℃~65℃

Can Body Material

SA516M Gr485

Nominal Shell Thickness Mm

10.13,12

Seal Thickness Mm

10.13,12

Anti Corrosion In Tank

LING LEAD 3-6mm

Net Weight Of Tank Kg

≈7800

Operation Quality Kg

36000

Max Play Loading Kg

28200

Loading And Unloading Type

Top

Accessories Configuration

Safety valve+bursting disc * 1, DN65

Gas phase valve * 2, DN40

Liquid phase valve (including siphon and liquid trap) * 1, DN40

Manhole * 1, DN500

Design/Manufacturing Standards

IMDG   CODE 2016,ADR/RID,49CFR,TIR,
  USDOT,T22 UN Portable Tank,   ASME BPVC Sec.Ⅷ Div.1-2017,GBC 46145

Third Party Inspection

BV/ ASME /TS


Attention:

The handling of the containers by using fork lift or similar device is not allowed.

Transportation

• by truck or freight train using vehicles equipped with approved twist locks which have to be in accordance with the relevant ISO -regulations.

• by vessels observing the regulations of stowage, separation and lashing. Special container vessels should be preferred. Attention: In case of transportation by truck or train total weight and dimensions have to be checked and compared with perhaps existing limitations. Unloading Of Bromine from ISO Containers (Three Valve) The ISO containers used for transportation of Bromine are of lead lined. So care shall be taken to ensure that no moisture / atmospheric air enters into the container.

 Dong Run ZE recommend Teflon lined rubber hoses for the unloading of the trucks.


 

FAQ

1.Are you trading company or manufacturer ?

We are Group Corporation manufacturer ,have Group Factories Contractor.  

2 .Can I have samples of this type of product to test the quality?  
Yes, you can buy any sample to test the quality,our MOQ is 1 unit.  

3. What's the delivery time and can you lower the price?  
It depends on your order.The delivery time is within 30~120 workdays after we received your prepayment. If you have placed an order of large quantities, then,of course, the price can be lowered.  
4.Can you supply some quick-wear parts?
Yes, we can supply the parts as your request,such as Manhole cover,discharge tube, hose pipe, Valves,gaskets,Botls and nuts etc.  
6.Do you have any used products for sale?
We have products in stock for choices,the prices are favorable,we'll show you our stock products if you need.

7.What's the payment terms?
TT 30% as deposit, balance before shipment by TT or at sight.  

8. How to guarantee customers get the goods smoothly after they payment?  
Don't worry,dear.We have joined the trade assurance,you can place the order by trade assurance,if we don't delivery products, the deposit will be returned to you.

9.How can you ensure the quality of the products?

Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.

Certifications  

Lead Lining Bromine T22 Un Portable ISO 20FT Tank Container 8.32m3 (Bromine Br2 isotanks UN1744)

Packaging & Shipping  

Lead Lining Bromine T22 Un Portable ISO 20FT Tank Container 8.32m3 (Bromine Br2 isotanks UN1744)

The IMO classifications for ISO Tank Containers has been replaced by the 'T' code system.
The T-Code system specifies the test pressure of each type of tank container, its shell thickness, the pressure relief set-up and the bottom and top outlet arrangement. T-Code instructions apply to dangerous goods in classes 1 and 3 through 9. Class 2.
The T-Code system for tank containers was introduced in 2001. The T-Code system identifies tank containers from T1 through T22 and identifies the type of cargoes each container is designed to carry.
ISO tank containers have to be manufactured in accordance with strict international codes fCryogenic Tank Container T70or worldwide carriage of by liquids whether by land or sea.
Whilst the following isn't a complete listing of the IMO types, it provides an indication of the original system of classification.
IMO Type 1 - Hazardous Tanks - approved for transportation of substances of Class 1 and Classes 3 through 9 where the liquids have a flashpoint of less than 0°C. Some examples of the types of liquids include explosives, flammable liquids, corrosive and toxic substances.
IMO Type 2 - Low Hazardous Tanks - approved for transportation of Class 3 substances that have a flashpoint of 0 - 61°C. Some examples of combustible liquids include diesel and cooking oils.
IMO Type 5 - Gas Tanks -  approved for transport of non-refrigerated liquefied gases of Class 2.

T23 PORTABLE TANK INSTRUCTION T23

UN No. Substance Minimum test pressure (bar)
3109 ORGANIC PEROXIDE, TYPE F, LIQUID
tert-Butyl hydro- peroxidea, not more than 72% with water
Cumyl hydro-peroxide, not more than 90% in diluent type A
Di-tert-butyl peroxide, not more than 32% in diluent type A
Isopropyl cumyl hydro- peroxide, not more than 72% in diluent type A
p-Menthyl hydro- peroxide, not more than 72% in diluent type A
Pinanyl hydro- peroxide, not more than 56% in diluent type A
4
3110 ORGANIC PEROXIDE TYPE F, SOLID
Dicumyl peroxideb
4
3119 ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED 4
tert-Amyl peroxyneodecanoate, not more than 47% in diluent type A
tert-Butyl peroxyacetate, not more than 32% in diluent type B
tert-Butyl peroxy-2- ethylhexanoate, not more than 32% in diluent type B

a Provided that steps have been taken to achieve the safety equivalence of 65% tert-Butyl hydroperoxide and 35% water.
b Maximum quantity per portable tank: 2000 kg.

UN
No.
Substance Minimum test pressure (bar) Control tempe- rature Emergency temperaturef
3119
(Cont'd)
tert-Butyl peroxypivalate, not more than 27% in diluent type B +5 °C +10 °C
tert-Butyl peroxy- 3,5,5-trimethyl- hexanoate, not more than 32% in diluent type B +35 °C +40 °C
Di-(3,5,5-trimethyl- hexanoyl) peroxide, not more than 38% in diluent type A or type B 0 °C +5 °C
Peroxyacetic acid, distilled, type F, stabilizedd +30 °C +35 °C
3120 ORGANIC PEROXIDE, TYPE F, SOLID, TEMPERATURE CONTROLLED 4 c c
3229 SELF-REACTIVE LIQUID TYPE F 4
3230 SELF-REACTIVE SOLID TYPE F 4
3239 SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED 4 c c
3240 SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED 4 c c


UN No. Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya Openings below liquid level Maximum filling ratio
1005 Ammonia, anhydrous 29.0
25.7
22.0
19.7
Allowed 0.53
1009 Bromotrifluoromethane (Refrigerant gas R 13B1) 38.0
34.0
30.0
27.5
Allowed 1.13
1010 Butadienes, stabilized 7.5
7.0
7.0
7.0
Allowed 0.55
1010 Butadienes and hydrocarbon mixture, stabilized Allowed
1011 Butane 7.0
7.0
7.0
7.0
Allowed 0.51
1012 Butylene 8.0
7.0
7.0
7.0
Allowed 0.53
1017 Chlorine 19.0
17.0
15.0
13.5
Not Allowed 1.25
1018 Chlorodifluoromethane (Refrigerant gas R 22) 26.0
24.0
21.0
19.0
Allowed 1.03
1020 Chloropentafluoroethane (Refrigerant gas R 115) 23.0
20.0
18.0
16.0
Allowed 1.06
1021 1-Chloro-
1,2,2,2-tetrafluoroethane (Refrigerant gas R 124)
10.3
9.8
7.9
7.0
Allowed 1.20
1027 Cyclopropane 18.0
16.0
14.5
13.0
Allowed 0.53
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya Openings below liquid level Maximum filling ratio
1028 Dichlorodifluoromethane (Refrigerant gas R 12) 16.0
15.0
13.0
11.5
Allowed 1.15
1029 Dichlorofluoromethane (Refrigerant gas R 21) 7.0
7.0
7.0
7.0
Allowed 1.23
1030 1,1-Difluoroethane (Refrigerant gas R 152a) 16.0
14.0
12.4
11.0
Allowed 0.79
1032 Dimethylamine, anhydrous 7.0
7.0
7.0
7.0
Allowed 0.59
1033 Dimethyl ether 15.5
13.8
12.0
10.6
Allowed 0.58
1036 Ethylamine 7.0
7.0
7.0
7.0
Allowed 0.61
1037 Ethyl chloride 7.0
7.0
7.0
7.0
Allowed 0.80
1040 Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 °C -
-
- 10.0
Not Allowed 0.78
1041 Ethylene oxide and carbon dioxide mixture with more than 9% but not more than 87% ethylene oxide Allowed
1055 Isobutylene 8.1
7.0
7.0
7.0
Allowed 0.52
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya Openings below liquid level Maximum filling ratio
1060 Methylacetylene and propadiene mixture, stabilized 28.0
24.5
22.0
20.0
Allowed 0.43
1061 Methylamine, anhydrous 10.8
9.6
7.8
7.0
Allowed 0.58
1062 Methyl bromide with not more than 2% chloropicrin 7.0
7.0
7.0
7.0
Not Allowed 1.51
1063 Methyl chloride (Refrigerant gas R 40) 14.5
12.7
11.3
10.0
Allowed 0.81
1064 Methyl mercaptan 7.0
7.0
7.0
7.0
Not Allowed 0.78
1067 Dinitrogen tetroxide 7.0
7.0
7.0
7.0
Not Allowed 1.30
1075 Petroleum gases, liquefied Allowed
1077 Propylene 28.0
24.5
22.0
20.0
Allowed 0.43
1078 Refrigerant gas, n.o.s. Allowed
1079 Sulphur dioxide 11.6
10.3
8.5
7.6
Not Allowed 1.23
1082 Trifluorochloroethylene, stabilized
(Refrigerant gas R 1113)
17.0
15.0
13.1
11.6
Not Allowed 1.13
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya Openings below liquid level Maximum filling ratio
1083 Trimethylamine, anhydrous 7.0
7.0
7.0
7.0
Allowed 0.56
1085 Vinyl bromide, stabilized 7.0
7.0
7.0
7.0
Allowed 1.37
1086 Vinyl chloride, stabilized 10.6
9.3
8.0
7.0
Allowed 0.81
1087 Vinyl methyl ether, stabilized 7.0
7.0
7.0
7.0
Allowed 0.67
1581 Chloropicrin and methyl bromide mixture with more than 2% chloropicrin 7.0
7.0
7.0
7.0
Not Allowed 1.51
1582 Chloropicrin and methyl chloride mixture 19.2
16.9
15.1
13.1
Not Allowed 0.81
1858 Hexafluoropropylene (Refrigerant gas R 1216) 19.2
16.9
15.1
13.1
Allowed 1.11
1912 Methyl chloride and methylene chloride mixture 15.2
13.0
11.6
10.1
Allowed 0.81
1958 1,2-Dichloro-1,1,2,2- tetrafluoroethane (Refrigerant gas R 114) 7.0
7.0
7.0
7.0
Allowed 1.30
1965 Hydrocarbon gas, mixture liquefied, n.o.s. Allowed
1969 Isobutane 8.5
7.5
7.0
7.0
Allowed 0.49
T50 PORTABLE TANK INSTRUCTION (cont'd) T50

This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section
6.7.3 shall be met.
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya Openings below liquid level Maximum filling ratio
1973 Chlorodifluoromethane and chloropentafluoroethane mixture with fixed boiling point,
with approximately 49% chlorodifluoromethane (Refrigerant gas R 502)
28.3
25.3
22.8
20.3
Allowed Normal 1.05
1974 Chlorodifluorobromomethane (Refrigerant gas R 12B1) 7.4
7.0
7.0
7.0
Allowed Normal 1.61
1976 Octafluorocyclobutane (Refrigerant gas RC 318) 8.8
7.8
7.0
7.0
Allowed Normal 1.34
1978 Propane 22.5
20.4
18.0
16.5
Allowed Normal 0.42
1983 1-Chloro-2,2,2-trifluoroethane (Refrigerant gas R 133a) 7.0
7.0
7.0
7.0
Allowed Normal 1.18
2035 1,1,1-Trifluoroethane (Refrigerant gas R 143a) 31.0
27.5
24.2
21.8
Allowed Normal 0.76
2424 Octafluoropropane (Refrigerant gas R 218) 23.1
20.8
18.6
16.6
Allowed Normal 1.07
2517 1-Chloro-1,1-difluoroethane (Refrigerant gas R 142b) 8.9
7.8
7.0
7.0
Allowed Normal 0.99
2602 Dichlorodifluoromethane and 1,1-difluoroethane azeotropic mixture with approximately 74% dichlorodifluoromethane (Refrigerant gas R 500) 20.0
18.0
16.0
14.5
Allowed Normal 1.01
T50 PORTABLE TANK INSTRUCTION (cont'd) T50

This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section
6.7.3 shall be met.
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya Openings below liquid level Pressure- relief requirementsb Maximum filling ratio
3057 Trifluoroacetyl chloride 14.6
12.9
11.3
9.9
Not allowed 1.17
3070 Ethylene oxide and dichlorodifluoromethane mixture with not more than 12.5% ethylene oxide 14.0
12.0
11.0
9.0
Allowed 1.09
3153 Perfluoro (methyl vinyl ether) 14.3
13.4
11.2
10.2
Allowed Normal 1.14
3159 1,1,1,2-Tetrafluoroethane (Refrigerant gas R 134a) 17.7
15.7
13.8
12.1
Allowed Normal 1.04
3161 Liquefied gas, flammable, n.o.s. Allowed Normal
3163 Liquefied gas, n.o.s. Allowed Normal
3220 Pentafluoroethane (Refrigerant gas R 125) 34.4
30.8
27.5
24.5
Allowed Normal 0.87
3252 Difluoromethane (Refrigerant gas R 32) 43.0
39.0
34.4
30.5
Allowed Normal 0.78
3296 Heptafluoropropane (Refrigerant gas R 227) 16.0
14.0
12.5
11.0
Allowed Normal 1.20
3297 Ethylene oxide and chlorotetrafluoroethane mixture, with not more than 8.8% ethylene oxide 8.1
7.0
7.0
7.0
Allowed Normal 1.16

T50 PORTABLE TANK INSTRUCTION (cont'd) T50

This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section
6.7.3 shall be met.
UN
No.
Non-refrigerated liquefied gases Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya Openings below liquid level Maximum filling ratio
3298 Ethylene oxide and pentafluoroethane mixture, with not more than 7.9% ethylene oxide 25.9
23.4
20.9
18.6
Allowed Normal 1.02
3299 Ethylene oxide and tetrafluoroethane mixture, with not more than 5.6% ethylene oxide 16.7
14.7
12.9
11.2
Allowed Normal 1.03
3318 Ammonia solution, relative density less than 0.880 at 15 °C in water, with more than 50% ammonia Allowed
3337 Refrigerant gas R 404A 31.6
28.3
25.3
22.5
Allowed Normal 0.84
3338 Refrigerant gas R 407A 31.3
28.1
25.1
22.4
Allowed Normal 0.95
3339 Refrigerant gas R 407B 33.0
29.6
26.5
23.6
Allowed Normal 0.95
3340 Refrigerant gas R 407C 29.9
26.8
23.9
21.3
Allowed Normal 0.95
3500 Chemical under pressure, n.o.s. Allowed TP43c
3501 Chemical under pressure, flammable, n.o.s. Allowed TP4c
3502 Chemical under pressure, toxic, n.o.s. Allowed TP4c
3503 Chemical under pressure, corrosive, n.o.s. Allowed TP4c
3504 Chemical under pressure, flammable, toxic, n.o.s. Allowed TP4c
3505 Chemical under pressure, flammable, corrosive, n.o.s. Allowed TP4c

Previous: 
Next: 

Contact

 Address: R 23, F4,New Factory (4), B1, Phase II, Dashu Industrial Village , Liufang Street ,Wuhan East Lake Hi-tech Development Zone, Wuhan City, Hubei Province,P.R.China
Keystone Vessel Manufacturing Co., Ltd 
 Add :No. 333 Youyi Second Road, Suixian Economic Development Zone, Suizhou City, Hubei Province, P.R.China
Phones: +86-152-7135-7675    https://ks-vessel.com
Email: isotanks@foxmail.com jin@ks-vessel.com
Keystone Vessel Manufacturing (M) Sdn. Bhd. 
Add:PT 25466, 25467 & Lot 18869, Batu 5 1/2, Jalan Kuala Sawah, 70300 Seremban, Negeri Sembilan, Malaysia.
Copyright © 2023-2033 Keystone Vessel (Wuhan) Co., Ltd , Keystone Vessel Manufacturing Co., Ltd  All Rights Reserved  Hubei Dong Runze Special Vehicle Equipment Co.,Ltd